#RailSeqPower ComponentTypeUpstream RailVinput (V)Vout (V)Iout (A)AnDAPT PMIC
1VCCINT, VCCBRM, VCCPINT1C220Sync Buck HCVIN1217ARD_X_Z70_A2_IC1
2MGTAVCC1C200Sync BuckVIN1215ARD_X_Z70_A2_IC1
3VCCAUX, VCCPAUX, VCCPLL2C200Sync BuckVIN121.82 + 0.5 + 0.12ARD_X_Z70_A2_IC1
4MGTAVTT2C200Sync BuckVIN121.22ARD_X_Z70_A2_IC1
5VCCO_DDR3C710SIM LDOVCCAUX1.81.50.5ARD_X_Z70_A2_IC1
6VCCO_PL3C150Async BuckVIN123.33ARD_X_Z70_A2_IC1
7VCCO_PS3C150Async BuckVIN123.32ARD_X_Z70_A2_IC1
8VTTDDR4C200Sync BuckVIN120.753ARD_X_Z70_A2_IC1
9MGTAVCCAUX, VCCADC4C750Load SwitchVCCAUX1.81.80.12ARD_X_Z70_A2_IC1